PlusPRO 2 Series ISO Rack/Tower
6000VA to 10000VA
Embedded with Isolation Transformer
The PlusPRO 2 Series ISO Rack/Tower 6000VA to 10000VA is a true double conversion online UPS with pure sinewave output, zero transfer time and enhanced capacity. Main UPS, isolation transformer and battery are in aplit 3U rack/tower convertible box individually. With split-type design, it flexibly complies with users' demand no matter for standard or long time operation.
Featuring 6000VA, 10000VA integrated with LCD display, high output power factor 0.9, outstanding performance, optional isolation transformer box and optional external battery bank, PlusPRO 2 Series ISO Rack/Tower 6000VA to 10000VA model stand out as high efficient online UPS during harsh mains condition for mission critical equipment in data/computer center or industrial applications.
●  High performance true double conversion Online UPS 6000VA to 10000VA
●  Isolation transformer in split rack box with maintenance bypass switch
●  N+X parallel redundancy and capacity expension (Optional)
●  External battery box to extend backup time (Optional)
●  Microprocessor control guarantees high reliability
●  Low heat dissipation in long time operation
●  Emergency power-off function (EPO)
●  Input THDi <5% / Output THD <2%
●  High efficiency mode (ECO mode)
●  Output voltage regulation +/-2%
●  Automatic self-testing function
●  Power management software
●  Fan speed control & DC start
●  Output power factor 0.9






PlusPRO 2-6K-ISOPlusPRO 2-10K-ISO
CAPACITY6KVA/5.4KW10KVA/9KW
INPUT
Phase1 Phase 2 Wires with Ground
Voltage220/230/240Vac
Frequency50Hz or 60Hz (Auto-sensing)
THDi<5% with R full load
OUTPUT
Phase1 Phase 3 Wires with Ground
Voltage220/110Vac, 230/115Vac, or 240/120Vac (set via control panel)
Voltage Regulation+/-2%
Frequency (Battery Mode)50Hz or 60Hz +/-0.05Hz
WaveformPure Sinewave
THD<2% (linear load), <5% (non-linear load) 
Crest Ratio3 : 1
EFFICIENCY
To AC Mode>92% at full load and battery fully charged
To Battery Mode>92% at full load and 12VDC/battery
To ECO Mode>96% at full load and battery fully charged
BATTERY
TypeMaintenance free sealed lead-acid battery
Voltage240VDC
Capacity & Number12V/7AH*20pcs12V/9AH*20pcs
Recharge Time7 hours to 90%8 hours to 90%
TRANSFER TIME
Line Mode to Battery Mode0ms
Inverter to Bypass0ms
ECO Mode to Inverter<10ms
DISPLAY
LED IndicatorNormal (Green), Bypass (Yellow), Fault (Red), Battery (Yellow)
LCD DisplayLoad level, Battery voltage, Battery mode, AC mode, Bypass mode information
AUDIBLE ALARM
Battery ModeBeeps Every 4 Seconds
Low BatterySounding Every Second
OverloadSounding Twice Every Second 
FaultBeeping Continuously
COMMUNICATIONS
Interface (Port)USB Port (Dry Contact is optional)
Intelligent SlotYes, but SNMP card is optional
EPOEmergency Power Off
ENVIRONMENT
Operating Temperature0°C-40°C (32°F-104°F)
Humidity0-95% (Non-condensing)
Acousitc Noise<50dB at 1M
PHYSICAL
Rack Height of Main UPS3U
Main UPS (D*W*H)610*440*135mm
Rack Height of Isolation Box3U
Isolation Box (D*W*H)610*440*135mm
Rack Height of Battery Box3U
Battery Box (D*W*H)610*440*135mm
*Product specifications are subject to change without further notice.